Appareillage de commutation SF6
  • KDM SF6 Switchgear support diverse industrial, commercial and utility power management requirements
  • Safety-conscious and nature-friendly electric distribution and substation solutions
  • Independent design to meet particular needs
  • OEM/ODM projects are operated professionally

Reliable SF6 Switchgear Supplier and Manufacturer in China

Need help for complete line of high-quality SF6 switchgear?

KDM has plenty stocks of nature-friendly and easier to assemble SF6 switchgear. Safety and effective switchgear help reduce overall cost which requires less maintenance. Our skilled engineers joined forces to design SF6 switchgears using advanced machinery and equipment.

KDM ensure to use popular and certified materials and parts for a longer life span and high performance.

KDM SF6 Switchgear Series

SF6 GIS Switchgear

KDM SF6 GIS Switchgear is constructed with premium quality raw material. It is suitable to withstand harsh and corrosive environments. The SF6 GIS Switchgear comes in a variety of options that are able to support various industry fields.

SF6 Medium Voltage Switchgear

Looking for a reliable SF6 Medium Voltage Switchgear supplier and manufacturer? KDM manufactures these operational units to be technologically-tested and quality-tested.

SF6 Ring Main Unit Switchgear

KDM design and manufacture SF6 Ring Main Unit Switchgear according to the national and international testing and standards. We had equipped with professional engineers that will help you construct components based on your equipment.

9 produits trouvés.

Send your Inquiry on KDM SF6 Switchgear

All KDM SF6 switchgear are fabricated by our trained and experienced craftsmen utilizing high end materials. We ensure to provide great satisfaction tested and proven by our big-time clients helps meet project needs.

KDM assure hassle-free and excellent solutions for your SF6 switchgear orders.

  • 50 technical engineers to expertly handled orders
  • Wide array of units available considering the required specifications
  • Cost-effective sf6 switchgear products
  • Modern technology machines to developed quality switchgear

Related Products of SF6 Switchgear

KDM SF6 Switchgear

Appareillage de commutation SF6

KDM sf6 switchgear is fabricated to provide safety and sustainability. In KDM, we designed sf6 switchgear to feature powerful benefits of commercial applications and data for grid. Our product uses pure vacuum interruption and air insulation to give primary and secondary innovations.

KDM sf6 switchgear is created to support and provide powerful digital technology. Our company is engaged to other large industrial and commercial business partners and building sectors where sf6 switchgear technology is operational today. Sf6 switchgears are costly today but we make sure that our sf6 switchgear achieves a level of cost efficiency. Designed through our advanced machines and progressive techniques, we are able to produce highly innovative, cost-saving SF6 switchgear.

Appareillage de commutation SF6

Our sf6 switchgear unlocks numerous benefits in digital industries. KDM emphasized the outstanding features given by our product. Our sf6 switchgear can unlock preventive and predictive asset management strategies by feeding data to analytics tools in sensors for condition monitors. We are so eager to manufacture and provide world-class sf6 switchgear all around the world.

With over a decade of experience in this industry, we developed a perfect sf6 switchgear that utilizes safety-conscious materials and environmentally responsible. We are well-equipped with modern technology machines that ensure the quality of our manufactured products.KDM assures you that our sf6 switchgear will never be maintenance intensive and will give damage to your equipment.

Appareillage de commutation SF6

KDM sf6 switchgear is handled by 50 technical engineers to sustain the development and support and check the manufacturing this products. We are creating and providing different types of sf6 switchgear considering the required specifications given by our customers and clients. In global system, KDM provides real-time control and operational efficiency to our largest partners and developer community.

KDM sf6 switchgear offer low cost of ownership over the complete cycle of your medium-voltage equipment. We believe that our sustainability, commitment to innovation and diversity ensures that life and technology is everywhere and for everyone. We treat our clients, customers and business partners as great people and give them the best quality sg6 switchgear and satisfy them with our services.

KDM aims to be a one stop solution for your sf6 switchgear needs, order or no order. Any types you need for sf6 switchgear, we will surely provide the best products at affordable price. We are happy to help your business grow in this industry.

For more informations you need for this products. Be sure to contact us! We are available 24/7 and happy to serve you as our dear customer. Check out KDM now!

Sf6 Switchgear: The Ultimate FAQ Guide

Without an advanced knowledge on Sf6 Switchgears, you may not be able to get one that serves the intended purpose.

However, with this guide, you’re going to become an expert in the Sf6 Switchgear.

This guide covers both basic and advanced concepts on this switchgear.

What is Sf6 Switchgear?

A Sf6 Switchgear is a type of switchgear that uses a special gas, Sf6, as its main insulation material.

It is basically an example of appareillage de commutation isolé au gaz.

Sf6 Switchgear

Sf6 Switchgear

What are the Benefits of Sf6 Switchgear?

The benefits of SF6 switchgear include:

Low Maintenance Cost.

The general maintenance cost of using an Sf6 Switchgear is less since there are fewer blackouts.

De plus, la non-réaction avec les composants de l'appareillage de commutation garantit leur durabilité, réduisant ainsi le coût global.

Minimizes on Space

An Sf6 Switchgear utilizes less space when you compare to Air Insulated Switchgear.

Sf6 Switchgear uses 10% of the space that Air Insulated Switchgear uses.

Vous pouvez donc utiliser cet appareillage dans des zones disposant de moins d'espace.

Environmentally Safe

L’utilisation du gaz Sf6 minimise la pollution environnementale car il ne réagit pas avec l’environnement.

De plus, le gaz ne réagit pas avec les matériaux de l'appareillage de commutation, ce qui évite tout effet négatif que de telles réactions pourraient avoir sur l'environnement.

Reliable

Sf6 Switchgear offers a reliable option than Air Insulated Switchgear.

Vous vous attendez à moins de pannes lorsque vous utilisez un appareillage de commutation isolé au gaz.

De plus, le taux de maintenance est très faible, ce qui signifie qu'il y a moins de mises hors tension de l'appareillage de commutation à des fins de maintenance.

Easy to Assemble

An Sf6 Switchgear is easy to assemble at the shop.

Il y a également la personnalisation des modules qui facilite le processus d'assemblage.

Are there Disadvantages of Sf6 Switchgear?

Yes. There are disadvantages to using Sf6 switchgear.

Ils comprennent :

Frequent Flashovers

A decrease in the pressure of the SF6 gas in any compartment of the Switchgear results in flashovers.

Il est nécessaire de surveiller fréquemment le niveau de pression pour s’assurer qu’il ne baisse pas.

High Initial Cost

The initial cost of purchasing an Sf6 Switchgear is relatively higher when you compare to purchasing Air Insulated Switchgear.

Requires Maximum Care

Dust contamination of live parts of Sf6 Switchgear is easy, which affects its performance.

There is, therefore, a need for maximum care to prevent dust contamination, which can be tedious.

High Outage Time

It takes a lot of time to identify ad diagnose a fault when it occurs.

Cela entraîne de nombreuses pannes de courant, qui affectent le fonctionnement de la centrale.

Where can you use Sf6 Switchgear?

You can use Sf6 switchgear in the following areas:

1. Environmentally Sensitive Installation

The characteristics of Sf6 Switchgear makes it an ideal option for environmentally sensitive installation.

C'est parce qu'ils peuvent être enfermés et qu'ils résistent à la foudre puisque les matériaux appartiennent à la cage de Faraday.

2. Urban Installations

You can use Sf6 Switchgear in areas where there is an appeal for real estate and price a critical component.

3. High Voltage Installation

An Sf6 Switchgear is common in common in applications that require high voltage since it utilizes a smaller space.

4. Underground Stations

Ils sont idéaux à utiliser car ils permettent un boîtier métallique.

What are the Components of Sf6 Switchgear?

The components of Sf6 switchgear include:

· Jeu de barres

Un jeu de barres est une barre ou une bande métallique dont la fonction est de connecter les équipements de tension à l'appareillage de commutation.

Ils transportent le courant dans l'appareillage de commutation.

Ils ne sont pas isolés et sont suffisamment rigides pour être suspendus à la balance grâce au soutien de piliers isolés.

· Transformateur de courant

The function of a current transformer is to multiply or reduce the electrical current in an Sf6 Switchgear.

Il aide à maintenir le courant entre les circuits primaires et secondaires de l'appareillage de commutation.

· Transformateur abaisseur

They help in the conversion of voltage from high to low, which the switchgear panel can use.

· Sectionneur de mise à la terre

Le sectionneur de mise à la terre permet de diriger l'excès de courant électrique dans l'appareillage vers la terre.

Cela contribue à réduire les surcharges électriques et l’apparition de défauts électriques.

· Interrupteur de déconnexion/isolateur

The function of a disconnecting switch in an Sf6 Switchgear is to interrupt small currents which are capacitively coupled or induced.

They are a crucial part, especially during maintenance of the Sf6Switchgear.

· Air Break Switches.

They help in the sustenance of two lines or equipment of the switchgear panel, thus minimizing electrocution.

Cela se fait par l'isolation du circuit et de l'équipement à l'intérieur de l'appareillage de commutation.

· Disjoncteur

Un disjoncteur permet d'arrêter le flux de courant excessif dans le circuit électrique.

Cela permet d'éviter que des défauts ne se produisent dans l'appareillage de commutation.

Il s'agit d'un revêtement métallique qui utilise du gaz SF6 pour l'interruption des défauts et l'isolation.

How does Sf6 Switchgear Work?

Sf6 Switchgear

 Sf6 Switchgear

The optimum functioning of the Sf6 switchgear depends on the performance of the individual components.

Lorsqu'un défaut survient, le relais entre en action en fermant le circuit de déclenchement.

Cela se fait par la déconnexion automatique de la ligne de défaut.

Ensuite, les sections saines et opérationnelles assurent un flux de la charge d’approvisionnement normale requise.

Grâce à cela, l'alimentation électrique de l'ensemble de l'équipement est fluide, ce qui garantit l'absence de dommages.

La surcharge de la ligne empêche le courant d'effectuer une action de libération électromagnétique.

Cependant, il initie la production de chaleur par l'élément thermique.

Le radiateur chauffe la feuille bimétallique, ce qui la fait se courber vers le haut.

Cela pousse le levier vers le haut, ce qui bloque le crochet.

Cela rompt le contact principal, coupant ainsi l'alimentation électrique.

En faisant cela, lorsqu'il y a une surcharge, celle-ci dépasse le courant réglé, ce qui fait que le déclencheur électromagnétique produit une aspiration.

A combination of the suction and the impact lever results in the lap hook to rotate upwards around the Shaft seat

Cela entraîne la libération du verrou.

Which features should you look for when Buying Sf6 Switchgear?

You need to check on the following features when buying an Sf6 switchgear

·  Sf6 Switchgear Material

Le type de métaux utilisés dans le processus de fabrication détermine l’application du panneau de commutation.

Vous devez donc tenir compte du type de métaux utilisés dans le processus de fabrication.

· Sécurité

The Sf6 switchgear that you purchase should be safe for both the electrical equipment and those who are operating it.

Un panneau de commutation efficace doit minimiser l’apparition de dangers pendant le fonctionnement.

Vous pouvez le vérifier en parcourant les spécifications et en consultant un expert.

· Espace

There are different sizes of Sf6 switchgear that utilize different spaces.

Before purchasing one, you should check on the space to ensure that you have enough for your Sf6 switchgear.

Space should allow for maintenance movements of the Sf6 Switchgear.

· Efficacité

The efficiency of your Sf6 switchgear is a critical aspect.

The Sf6 switchgear should be able to operate with minimal interference and maximum output.

Cela garantit une productivité et une continuité maximales dans vos applications.

· Réputation du fabricant

You need to purchase your Sf6 Switchgear from a reputable manufacturer.

Cela garantit sa durabilité et sa qualité.

Ils sont également en mesure de réparer et d'entretenir votre tableau électrique lorsque celui-ci rencontre des problèmes durant sa période de garantie.

· Allocation future

The perfect Sf6 switchgear should last an average of 30 years.

C'est trop long pour que de nouveaux développements puissent se produire, comme des équipements supplémentaires.

Il devrait donc être en mesure de répondre à ces besoins futurs puisqu’il s’agit d’un équipement durable.

· Garantie

Quality Sf6 switchgear will have a warranty period.

Durant cette période, vous pouvez librement le retourner pour réparation conformément aux conditions de la garantie

Which Types of Sf6 Switchgear are there?

There are three types of Sf6 Switchgears available.

Ils sont:

  • Low voltage Sf6 switchgear connects and disconnects, distributes and interrupts current flow with a voltage of up to 600V
  • Medium Voltage Sf6 switchgear isolates, distributes, connects, and disconnects power system with a voltage range of between 600V and 69kV
  • High Voltage Sf6 switchgear connects and disconnects, interrupts, and distributes current with a voltage of between 69kV and 230kV.

How does Screened Sf6 Switchgear compare to Normal Sf6 Switchgear?

A Screened Sf6 switchgear offers excellent electromagnetic interference resistance when you compare to normal Sf6 switchgear.

How do you Test Sf6 Switchgear?

You need to conduct the following test when testing Sf6 switchgear:

· Test du noyau du transformateur de courant

Vous devez tester le rapport et la polarité du noyau du transformateur de courant et comparer les résultats à l'injection de courant primaire.

Vous devez effectuer ce test phase par phase.

· Test diélectrique

Le test diélectrique est effectué sur les circuits auxiliaires.

Pour ce test, appliquez une tension continue de 500 V entre les borniers et le point de terre.

· Tests de tension sur le circuit principal

Il est nécessaire de vérifier la rigidité diélectrique pour éliminer les causes telles que les dommages lors de la manipulation, une mauvaise fixation et la présence de corps étrangers.

De tels problèmes peuvent entraîner un dysfonctionnement interne de l'appareillage de commutation s'ils ne sont pas résolus.

· Résistance aux courts-circuits

Cet essai détermine la résistance des jeux de barres et de leurs dispositifs de coupure, de supports et de protection aux contraintes électrodynamiques et thermiques.

· Limites d'augmentation de la température

Temperature rise limits help in determining the appropriate operating temperature for Sf6 switchgear.

High temperature has the effect of components aging prematurely, leading to the failure of the Sf6 switchgear.

· Vérification du degré opérationnel

This test determines the operational safety of the Sf6 Switchgear.

Il permet également d’empêcher les contaminants solides et liquides d’entrer en contact avec l’appareillage de commutation.

· Ligne de fuite et distance de sécurité

You need to carry out this test between the live parts of the Sf6 Switchgear and also its exposed conductive parts.

Vous mesurez la distance entre les pièces sous tension en utilisant les différentes polarités.

Les assemblages boulonnés, les joints, les connecteurs inadaptés minimisent les valeurs d'isolation initiales.

· Efficacité du circuit de protection

This helps in determining the safety of the Sf6 switchgear.

Ce test permet également de déterminer l'apparition d'un courant de défaut élevé en cas de détachement accidentel du conducteur.

Les circuits de protection efficaces doivent résister à une contrainte thermique de court-circuit optimale, qui se produit en fonction du courant d'alimentation.

How can you Troubleshoot Sf6 Switchgear?

Troubleshooting Sf6 switchgear depends on the cause of the problem.

The following are the solution to the main Sf6 Switchgear problems.

i. Shutters not Closing

La principale raison pour laquelle l'obturateur ne se ferme pas est due à des obturateurs endommagés.

Pour résoudre ce problème, vous devez réparer les volets et nettoyer les pièces réglables.

Vous pouvez également appliquer une huile lubrifiante dans ces pièces pour faciliter la fermeture.

ii. Indicating Light Extinction

L'extinction de la lumière peut être le résultat des éléments suivants :

Fusible ou résistance grillé, filament d'ampoule cassé, contacteur de fin de course défectueux, mauvais contact des interrupteurs auxiliaires.

Pour résoudre ce problème, vous devez vérifier les éléments suivants : changer l'ampoule, remplacer le fusible ou la résistance, nettoyer les contacts auxiliaires ou surveiller le MCCB des bornes du fusible.

iii. You cannot Lock the Handle

Ce problème provient de la rouille du mécanisme de verrouillage interne ou d'un mécanisme de verrouillage défectueux.

Il se peut également que vous utilisiez la mauvaise clé pour l'ouvrir.

Pour résoudre ce problème, assurez-vous d’utiliser la bonne clé.

Vous devez lubrifier le mécanisme de verrouillage ou le remplacer complètement.

iv. Poor Control Unit Operation

Un mauvais fonctionnement de l'unité de commande peut être dû à des vis desserrées des borniers.

Alternativement, cela peut être dû à une mauvaise connexion de la prise de commande.

Vous devez serrer les vis des borniers. Vous pouvez également connecter les fiches de commande de manière appropriée.

v. Shutters are not Opening

Si vos volets ne s'ouvrent pas, cela peut être dû à un mauvais réglage des pièces mobiles ou à un manque de lubrification de ces pièces.

Cela peut également être dû à des volets déformés.

Pour résoudre ce problème, vous devez régler et lubrifier les pièces mobiles et vérifier les volets pour vous assurer qu'ils ne sont pas de bonne forme.

vi. Internal Noise

la cause du bruit interne produit par votre appareillage de commutation est due aux vis d'induction électromagnétique qui se trouvent sur les plaques de séparation.

Les câbles en contact avec les plaques presse-étoupes sont une autre source de bruit interne.

Assurez-vous d'avoir serré les vis sur les plaques de répartition et d'avoir appliqué une couche de produit d'étanchéité sur le câble.

vii. Overheated Connections

Ceci est dû au fait que les boulons sont en hauteur et desserrés.

To solve this, ensure that you use the rated current value. Also, tighten any loose bolt and replace the busbar if necessary.

viii. The switchgear Fails the Dielectric Test or Ground Fault.

Cela est dû à des isolateurs fissurés, qui sont sensibles à l'humidité ou aux contaminants étrangers.

Pour résoudre ce problème, vous devez remplacer les isolateurs.

Vous pouvez également nettoyer à l'aide d'un produit nettoyant approprié et sécher les parties humides.

What are Sf6 Switchgear Quality Certificates?

The following are the necessary quality certificates for a Sf6 Switchgear:

  • Normes nationales américaines pour les isolateurs (ANI).
  • Normes du Comité électrotechnique international (CEI).
  • Normes de la National Electrical Manufacturer Association (NEMA).
  • Association des normes de l'Institut des ingénieurs électriciens et électroniciens (IEEE-SA)
  • Normes ISO

Which Safety Features does Sf6 Switchgear come with?

The safety features available in Sf6 switchgear include:

· Suivi à distance

Le suivi à distance permet le retrait ou l'installation de disjoncteurs depuis l'extérieur d'une limite d'arc électrique.

· Commutation à distance

Remove Switching allows for remote charging, closing or opening of the switches and circuit breakers from a within a safe distance.

· Verrouillage/étiquetage

Il permet la personnalisation des procédures de verrouillage et d'étiquetage permanentes ou temporaires en fonction de l'application du client

Is Sf6 Switchgear Environmentally Friendly?

Oui.

Sf6 switchgear is environmentally safe.

This is due to the use of Sf6 gas, which is a non-toxic, colorless, and odorless gas that has a minimal negative effect on the environment.

How does Sf6 Switchgear compare to Sf6 Circuit Breaker?

An Sf6 circuit breaker is a component of Sf6 switchgear.

The function of an Sf6 Switchgear is to distribute, connect, and disconnect the power system.

The function of a circuit breaker is to protect electrical distribution systems and power supplies.

Are there Alternatives to Sf6 Switchgears?

Yes. There are alternatives to Sf6 Switchgears.

Ils comprennent :

Sf6 Circuit breaker

 Sf 6 Circuit Breaker

  • Carbon Dioxide Switchgears uses carbon dioxide as the main insulation material. It is a better alternative since it reduces greenhouse gas emissions better than Sf6 gas.
  • Air-insulated Switchgear uses compressed air as the main insulation material. It’s a cheaper alternative to Sf6 switchgear since it is easily available.
  • Oil Switchgear uses vaporized oil as the main insulation material. It is the oldest type of switchgear.
  • Hybrid switchgear combines both air and gas properties, which act as the main insulation material for the switchgear. It features a compact and modest design containing different functions in a single module.

Other alternatives include Fluor ketone, carbon dioxide, and oxygen for high-voltage (HV) switchgear and Fluor ketone, nitrogen and oxygen for medium-voltage (MV) switchgear.

What is Sf6 Switchgear Specification?

The main specifications for Sf6 Switchgear include:

· Fiabilité

An Sf6 Switchgear offers a reliable option against power interruption.

Cela est dû à la disponibilité du gaz SF6 qui n’est pas sujet aux pannes.

La fonction de maintenance zéro permet de réduire les interruptions de courant, ce qui garantit que les particuliers et les installations puissent bénéficier des services électriques.

· Distance de dégagement

La distance de dégagement est la plus petite distance dans l'air entre deux matériaux conducteurs.

Il est essentiel d’empêcher la rupture diélectrique qui se produit entre deux électrodes en raison de l’ionisation de l’air.

· Espace

Sf6 switchgear is a space utilizing switchgear.

La petite taille réduit l'espace d'installation par rapport à l'appareillage de commutation isolé à l'air.

Sf6 Switchgear uses 10% of the space that Air Insulated Switchgear uses.

Cette fonctionnalité élargit ses domaines d’application.

· Distance de fuite

Il s'agit d'une mesure de la plus petite distance sur la surface de l'isolation entre deux matériaux conducteurs.

En raison d'une décharge électrique, une corrosion se produit autour de la surface de cette région.

Il est donc important de maintenir la distance de fuite grâce à un processus appelé suivi.

Vous devez prendre en compte l’indice de suivi comparatif et le niveau de pollution atmosphérique lors de la vérification du suivi.

· Entretien

Sf6 Switchgear requires less maintenance, which helps in reducing the overall cost of the switchgear.

Cela est dû au nombre réduit de défauts qui se produisent et à la nature inerte du gaz SF6.

Envoyez votre demande aujourd'hui
Télécharger le fichier
fr_FRFrench
Retour en haut