Aparatos de distribución de SF6
  • KDM SF6 Switchgear support diverse industrial, commercial and utility power management requirements
  • Safety-conscious and nature-friendly electric distribution and substation solutions
  • Independent design to meet particular needs
  • OEM/ODM projects are operated professionally

Reliable SF6 Switchgear Supplier and Manufacturer in China

Need help for complete line of high-quality SF6 switchgear?

KDM has plenty stocks of nature-friendly and easier to assemble SF6 switchgear. Safety and effective switchgear help reduce overall cost which requires less maintenance. Our skilled engineers joined forces to design SF6 switchgears using advanced machinery and equipment.

KDM ensure to use popular and certified materials and parts for a longer life span and high performance.

KDM SF6 Switchgear Series

12kV SF6 Switchgear

KDM 12kV SF6 switchgear intended for power transmission and substation distribution are offered in various advantageous features. Reliable, compact, flexible, and operational unit for effective, minimal installation area and for better personnel safety.

24kV SF6 Switchgear

Our 24kV SF6 Switchgear is suitable for electric distribution and substation.  Compact, reliable and efficient switchgear that can provide satisfactory projects both -application and users.

33kV SF6 Switchgear

KDM 33kV SF6 switchgear suitable for electrical energy distribution, control, and with a degree of protection. For any harsh environmental conditions like heavy pollution, flood and others, our units are the ideal equipment.

Indoor SF6 Switchgear

Together with our skilled workers and technically-advanced manufacturing unit, KDM manufactures indoor SF6 switchgear in the highest quality standard. Our offered panel is assembled through our quality components and advanced techniques with compliance with international requirements.

Outdoor SF6 Switchgear

In KDM, we have a wide range of outdoor SF6 switchgear that is advantageous and has operational features. User-friendly, easy to operate, reliable and compact panel. This is available at a very reasonable cost.

Cuadros de distribución de alta tensión sin SF6

Are you looking for the best SF6 Free HV Switchgear for your business or industrial requirements? KDM has a variety of SF6 free HV switchgear solutions that are environmental-friendly and safety conscious.

9 productos encontrados.

Send your Inquiry on KDM SF6 Switchgear

All KDM SF6 switchgear are fabricated by our trained and experienced craftsmen utilizing high end materials. We ensure to provide great satisfaction tested and proven by our big-time clients helps meet project needs.

KDM assure hassle-free and excellent solutions for your SF6 switchgear orders.

  • 50 technical engineers to expertly handled orders
  • Wide array of units available considering the required specifications
  • Cost-effective sf6 switchgear products
  • Modern technology machines to developed quality switchgear

Related Products of SF6 Switchgear

KDM SF6 Switchgear

Aparatos de distribución de SF6

KDM sf6 switchgear is fabricated to provide safety and sustainability. In KDM, we designed sf6 switchgear to feature powerful benefits of commercial applications and data for grid. Our product uses pure vacuum interruption and air insulation to give primary and secondary innovations.

KDM sf6 switchgear is created to support and provide powerful digital technology. Our company is engaged to other large industrial and commercial business partners and building sectors where sf6 switchgear technology is operational today. Sf6 switchgears are costly today but we make sure that our sf6 switchgear achieves a level of cost efficiency. Designed through our advanced machines and progressive techniques, we are able to produce highly innovative, cost-saving SF6 switchgear.

Aparatos de distribución de SF6

Our sf6 switchgear unlocks numerous benefits in digital industries. KDM emphasized the outstanding features given by our product. Our sf6 switchgear can unlock preventive and predictive asset management strategies by feeding data to analytics tools in sensors for condition monitors. We are so eager to manufacture and provide world-class sf6 switchgear all around the world.

With over a decade of experience in this industry, we developed a perfect sf6 switchgear that utilizes safety-conscious materials and environmentally responsible. We are well-equipped with modern technology machines that ensure the quality of our manufactured products.KDM assures you that our sf6 switchgear will never be maintenance intensive and will give damage to your equipment.

Aparatos de distribución de SF6

KDM sf6 switchgear is handled by 50 technical engineers to sustain the development and support and check the manufacturing this products. We are creating and providing different types of sf6 switchgear considering the required specifications given by our customers and clients. In global system, KDM provides real-time control and operational efficiency to our largest partners and developer community.

KDM sf6 switchgear offer low cost of ownership over the complete cycle of your medium-voltage equipment. We believe that our sustainability, commitment to innovation and diversity ensures that life and technology is everywhere and for everyone. We treat our clients, customers and business partners as great people and give them the best quality sg6 switchgear and satisfy them with our services.

KDM aims to be a one stop solution for your sf6 switchgear needs, order or no order. Any types you need for sf6 switchgear, we will surely provide the best products at affordable price. We are happy to help your business grow in this industry.

For more informations you need for this products. Be sure to contact us! We are available 24/7 and happy to serve you as our dear customer. Check out KDM now!

Sf6 Switchgear: The Ultimate FAQ Guide

Without an advanced knowledge on Sf6 Switchgears, you may not be able to get one that serves the intended purpose.

However, with this guide, you’re going to become an expert in the Sf6 Switchgear.

This guide covers both basic and advanced concepts on this switchgear.

What is Sf6 Switchgear?

A Sf6 Switchgear is a type of switchgear that uses a special gas, Sf6, as its main insulation material.

It is basically an example of Aparato de distribución aislado en gas.

Aparatos de distribución de Sf6

Aparatos de distribución de Sf6

What are the Benefits of Sf6 Switchgear?

The benefits of SF6 switchgear include:

Low Maintenance Cost.

The general maintenance cost of using an Sf6 Switchgear is less since there are fewer blackouts.

Además, la no reacción con los componentes del cuadro de distribución garantiza que sean duraderos, lo que reduce el coste general.

Minimizes on Space

An Sf6 Switchgear utilizes less space when you compare to Air Insulated Switchgear.

Sf6 Switchgear uses 10% of the space that Air Insulated Switchgear uses.

Por lo tanto, puede utilizar este cuadro de distribución en zonas con menos espacio.

Environmentally Safe

El uso de gas Sf6 minimiza la contaminación ambiental ya que no reacciona con el medio ambiente.

Además, el gas no reacciona con los materiales del cuadro de distribución, lo que evita cualquier efecto negativo que dichas reacciones puedan tener sobre el medio ambiente.

Reliable

Sf6 Switchgear offers a reliable option than Air Insulated Switchgear.

Se esperan menos cortes de energía al utilizar tableros de distribución con aislamiento de gas.

Además, la tasa de mantenimiento es muy baja, lo que significa que hay menos paradas del cuadro de distribución para fines de mantenimiento.

Easy to Assemble

An Sf6 Switchgear is easy to assemble at the shop.

Además, existe la personalización de los módulos que facilitan el proceso de montaje.

Are there Disadvantages of Sf6 Switchgear?

Yes. There are disadvantages to using Sf6 switchgear.

Entre ellos se incluyen:

Frequent Flashovers

A decrease in the pressure of the SF6 gas in any compartment of the Switchgear results in flashovers.

Es necesario controlar con frecuencia el nivel de presión para garantizar que no baje.

High Initial Cost

The initial cost of purchasing an Sf6 Switchgear is relatively higher when you compare to purchasing Air Insulated Switchgear.

Requires Maximum Care

Dust contamination of live parts of Sf6 Switchgear is easy, which affects its performance.

There is, therefore, a need for maximum care to prevent dust contamination, which can be tedious.

High Outage Time

It takes a lot of time to identify ad diagnose a fault when it occurs.

Esto provoca grandes cortes de electricidad que afectan al funcionamiento de la planta.

Where can you use Sf6 Switchgear?

You can use Sf6 switchgear in the following areas:

1. Environmentally Sensitive Installation

The characteristics of Sf6 Switchgear makes it an ideal option for environmentally sensitive installation.

Esto se debe a que se pueden encerrar y son resistentes a los rayos ya que los materiales pertenecen a la Jaula de Faraday.

2. Urban Installations

You can use Sf6 Switchgear in areas where there is an appeal for real estate and price a critical component.

3. High Voltage Installation

An Sf6 Switchgear is common in common in applications that require high voltage since it utilizes a smaller space.

4. Underground Stations

Son ideales para su uso ya que permiten un cerramiento metálico.

What are the Components of Sf6 Switchgear?

The components of Sf6 switchgear include:

· Barra colectora

Un embarrado es una barra o tira metálica cuya función es conectar equipos en tensión a la aparamenta.

Conducen la corriente dentro del cuadro de distribución.

No están aislados y son lo suficientemente rígidos como para mantenerse en equilibrio con el apoyo de pilares aislados.

· Transformador de corriente

The function of a current transformer is to multiply or reduce the electrical current in an Sf6 Switchgear.

Ayuda a mantener la corriente entre los circuitos primario y secundario del tablero de distribución.

· Step-down Transformer

They help in the conversion of voltage from high to low, which the switchgear panel can use.

· Interruptor de puesta a tierra

El seccionador de puesta a tierra ayuda a dirigir el exceso de corriente eléctrica en el tablero de distribución hacia tierra.

Esto ayuda a reducir la sobrecarga eléctrica y la aparición de fallas eléctricas.

· Interruptor de desconexión/aislador

The function of a disconnecting switch in an Sf6 Switchgear is to interrupt small currents which are capacitively coupled or induced.

They are a crucial part, especially during maintenance of the Sf6Switchgear.

· Air Break Switches.

They help in the sustenance of two lines or equipment of the switchgear panel, thus minimizing electrocution.

This is through isolation of circuit and equipment within the switchgear.

· Disyuntor

Un disyuntor ayuda a detener el flujo excesivo de corriente en el circuito eléctrico.

Esto ayuda a evitar que se produzcan fallos dentro del cuadro de distribución.

Es un revestimiento metálico que utiliza gas SF6 para interrupción de fallas y aislamiento.

How does Sf6 Switchgear Work?

Aparatos de distribución de Sf6

 Aparatos de distribución de Sf6

The optimum functioning of the Sf6 switchgear depends on the performance of the individual components.

Cuando ocurre una falla, el relé entra en acción cerrando el circuito de disparo.

Esto se realiza mediante la desconexión automática de la línea de falla.

A continuación, las secciones sanas y operativas garantizan que haya un flujo de la carga de suministro normal requerida.

Gracias a esto, se consigue un suministro eléctrico fluido en todo el equipo, garantizando que no se produzcan daños.

La sobrecarga de la línea inhibe que la corriente realice una acción de liberación electromagnética.

Sin embargo, inicia la producción de calor por parte del elemento térmico.

El calentador calienta la lámina bimetálica provocando que se doble hacia arriba.

Esto empuja la palanca hacia arriba, haciendo que el gancho se bloquee.

Esto interrumpe el contacto primario y corta el suministro de energía.

De esta manera, cuando hay una sobrecarga, se supera la corriente establecida provocando que el disparador electromagnético produzca succión.

A combination of the suction and the impact lever results in the lap hook to rotate upwards around the Shaft seat

This results in the release of the lock.

Which features should you look for when Buying Sf6 Switchgear?

You need to check on the following features when buying an Sf6 switchgear

·  Sf6 Switchgear Material

El tipo de metales utilizados en el proceso de fabricación determina la aplicación del panel de distribución.

Por lo tanto, es necesario tener en cuenta el tipo de metales utilizados en el proceso de fabricación.

· Seguridad

The Sf6 switchgear that you purchase should be safe for both the electrical equipment and those who are operating it.

Un panel de distribución eficaz debe minimizar la aparición de riesgos durante el funcionamiento.

Puedes comprobarlo consultando las especificaciones y un experto.

· Espacio

There are different sizes of Sf6 switchgear that utilize different spaces.

Before purchasing one, you should check on the space to ensure that you have enough for your Sf6 switchgear.

Space should allow for maintenance movements of the Sf6 Switchgear.

· Eficiencia

The efficiency of your Sf6 switchgear is a critical aspect.

The Sf6 switchgear should be able to operate with minimal interference and maximum output.

Esto garantiza la máxima productividad y continuidad en sus aplicaciones.

· Reputación del fabricante

You need to purchase your Sf6 Switchgear from a reputable manufacturer.

Esto garantiza su durabilidad y calidad.

También pueden reparar y realizar el mantenimiento de su panel de distribución cuando presente problemas durante su período de garantía.

· Subsidio Futuro

The perfect Sf6 switchgear should last an average of 30 years.

Este tiempo es demasiado largo para que se puedan producir nuevos desarrollos, como por ejemplo equipos adicionales.

Por lo tanto, debería ser capaz de satisfacer estas necesidades futuras, ya que es un equipo duradero.

· Garantía

Quality Sf6 switchgear will have a warranty period.

Durante este período, puede devolverlo libremente para su reparación de acuerdo con los términos de la garantía.

Which Types of Sf6 Switchgear are there?

There are three types of Sf6 Switchgears available.

Ellos son:

  • Low voltage Sf6 switchgear connects and disconnects, distributes and interrupts current flow with a voltage of up to 600V
  • Medium Voltage Sf6 switchgear isolates, distributes, connects, and disconnects power system with a voltage range of between 600V and 69kV
  • High Voltage Sf6 switchgear connects and disconnects, interrupts, and distributes current with a voltage of between 69kV and 230kV.

How does Screened Sf6 Switchgear compare to Normal Sf6 Switchgear?

A Screened Sf6 switchgear offers excellent electromagnetic interference resistance when you compare to normal Sf6 switchgear.

How do you Test Sf6 Switchgear?

You need to conduct the following test when testing Sf6 switchgear:

· Prueba del núcleo del transformador de corriente

Es necesario probar la relación y la polaridad del núcleo del transformador de corriente y comparar los resultados con la inyección de corriente primaria.

Es necesario realizar esta prueba fase por fase.

· Prueba dieléctrica

La prueba dieléctrica se realiza en los circuitos auxiliares.

Para esta prueba, aplique 500 voltios CC entre los bloques de terminales y el punto de tierra.

· Pruebas de voltaje en el circuito principal

Es necesario comprobar la rigidez dieléctrica para eliminar causas como daños durante la manipulación, fijación incorrecta y presencia de cuerpos extraños.

Estos problemas pueden provocar un mal funcionamiento interno del cuadro de distribución si no se solucionan.

· Resistencia a cortocircuitos

Este ensayo determina la resistencia de las barras colectoras y sus dispositivos de rotura, soportes y protección a la tensión electrodinámica y térmica.

· Límites de aumento de temperatura

Temperature rise limits help in determining the appropriate operating temperature for Sf6 switchgear.

High temperature has the effect of components aging prematurely, leading to the failure of the Sf6 switchgear.

· Comprobación del grado de operatividad

This test determines the operational safety of the Sf6 Switchgear.

También ayuda a evitar que contaminantes sólidos y líquidos entren en contacto con el tablero de distribución.

· Distancia de fuga y de espacio libre

You need to carry out this test between the live parts of the Sf6 Switchgear and also its exposed conductive parts.

Mide la distancia entre las partes activas utilizando las diferentes polaridades.

Las uniones atornilladas, las uniones y los conectores inadecuados minimizan los valores iniciales de aislamiento.

· Eficacia del circuito de protección

This helps in determining the safety of the Sf6 switchgear.

Esta prueba también determina la ocurrencia de una corriente de falla alta en caso de que el conductor se desprenda accidentalmente.

Los circuitos de protección eficaces deben soportar un estrés térmico de cortocircuito óptimo, lo que se produce según la corriente de suministro.

How can you Troubleshoot Sf6 Switchgear?

Troubleshooting Sf6 switchgear depends on the cause of the problem.

The following are the solution to the main Sf6 Switchgear problems.

i. Shutters not Closing

La razón principal por la que la persiana no se cierra se debe a persianas dañadas.

Para solucionar esto es necesario reparar las persianas y limpiar las partes ajustables.

También puedes aplicar un aceite lubricante en estas partes para facilitar el cierre.

ii. Indicating Light Extinction

La extinción de la luz indicadora puede deberse a lo siguiente:

Fusible o resistencia quemado, filamento de bombilla roto, contactor de final de carrera defectuoso, mal contacto de los interruptores auxiliares.

Para solucionar esto es necesario verificar lo siguiente: cambiar la bombilla, reemplazar el fusible o la resistencia, limpiar los contactos auxiliares o monitorear el MCCB de los terminales del fusible.

iii. You cannot Lock the Handle

Este problema surge de la oxidación del mecanismo de bloqueo interno o de un mecanismo de bloqueo defectuoso.

También puede ser que estés usando la llave incorrecta para abrir.

Para solucionar este problema, asegúrese de utilizar la clave correcta.

Es necesario lubricar el mecanismo de bloqueo o reemplazarlo por completo.

iv. Poor Control Unit Operation

El mal funcionamiento de la unidad de control puede deberse a tornillos sueltos de los bloques de terminales.

Alternativamente, puede deberse a una conexión incorrecta del enchufe de control.

Es necesario apretar los tornillos de los bloques de terminales. También puedes conectar los enchufes de control de forma adecuada.

v. Shutters are not Opening

Si sus persianas no abren puede ser debido a un mal ajuste de las partes móviles o falta de lubricación en estas partes.

También puede deberse a persianas deformadas.

Para solucionar esto, es necesario ajustar y lubricar las partes móviles y verificar las persianas para asegurarse de que tengan la forma incorrecta.

vi. Internal Noise

La causa de que su cuadro eléctrico produzca ruido interno se debe a los tornillos de inducción electromagnética que se encuentran en las placas divisorias.

Los cables que tocan las placas de prensaestopas son otra fuente de ruido interno.

Asegúrese de haber apretado los tornillos en las placas de porcionado y de haber aplicado una capa de sellador en el cable.

vii. Overheated Connections

Esto es el resultado de tener tornillos que están arriba y sueltos.

To solve this, ensure that you use the rated current value. Also, tighten any loose bolt and replace the busbar if necessary.

viii. The switchgear Fails the Dielectric Test or Ground Fault.

Los aisladores agrietados son la causa de este problema, ya que son propensos a la humedad o a contaminantes extraños.

Para solucionar esto es necesario sustituir los aisladores.

También puedes limpiarlo con un producto de limpieza adecuado y secar las partes húmedas.

What are Sf6 Switchgear Quality Certificates?

The following are the necessary quality certificates for a Sf6 Switchgear:

  • Normas de la Asociación Estadounidense de Normas Nacionales para Aisladores (ANI).
  • Normas del Comité Electrotécnico Internacional (IEC).
  • Normas de la Asociación Nacional de Fabricantes Eléctricos (NEMA).
  • Asociación de Normas del Instituto de Ingenieros Eléctricos y Electrónicos (IEEE-SA)
  • Normas ISO

Which Safety Features does Sf6 Switchgear come with?

The safety features available in Sf6 switchgear include:

· Remote Tracking

Remote tracking enables the removal or installation of circuit breakers from the outside of an arc flash boundary.

· Remote Switching

Remove Switching allows for remote charging, closing or opening of the switches and circuit breakers from a within a safe distance.

· Lock-out/Tag-out

It allows for permanent or temporary lockout Tag-out procedures customization as per the client’s application

Is Sf6 Switchgear Environmentally Friendly?

Sí.

Sf6 switchgear is environmentally safe.

This is due to the use of Sf6 gas, which is a non-toxic, colorless, and odorless gas that has a minimal negative effect on the environment.

How does Sf6 Switchgear compare to Sf6 Circuit Breaker?

An Sf6 circuit breaker is a component of Sf6 switchgear.

The function of an Sf6 Switchgear is to distribute, connect, and disconnect the power system.

The function of a circuit breaker is to protect electrical distribution systems and power supplies.

Are there Alternatives to Sf6 Switchgears?

Yes. There are alternatives to Sf6 Switchgears.

Entre ellos se incluyen:

Sf6 Circuit breaker

 Sf 6 Circuit Breaker

  • Carbon Dioxide Switchgears uses carbon dioxide as the main insulation material. It is a better alternative since it reduces greenhouse gas emissions better than Sf6 gas.
  • Air-insulated Switchgear uses compressed air as the main insulation material. It’s a cheaper alternative to Sf6 switchgear since it is easily available.
  • Oil Switchgear uses vaporized oil as the main insulation material. It is the oldest type of switchgear.
  • Hybrid switchgear combines both air and gas properties, which act as the main insulation material for the switchgear. It features a compact and modest design containing different functions in a single module.

Other alternatives include Fluor ketone, carbon dioxide, and oxygen for high-voltage (HV) switchgear and Fluor ketone, nitrogen and oxygen for medium-voltage (MV) switchgear.

What is Sf6 Switchgear Specification?

The main specifications for Sf6 Switchgear include:

· Fiabilidad

An Sf6 Switchgear offers a reliable option against power interruption.

Esto se debe a la disponibilidad del gas SF6 que no es propenso a fallas.

La función de mantenimiento cero permite menos interrupciones de energía, lo que garantiza que las personas y las plantas puedan disfrutar de los servicios de energía.

· Distancia de separación

La distancia libre es la distancia más pequeña a través del aire entre dos materiales conductores.

Es fundamental para prevenir la ruptura dieléctrica que se produce entre dos electrodos debido a la ionización del aire.

· Espacio

Sf6 switchgear is a space utilizing switchgear.

El tamaño pequeño reduce el espacio de instalación en comparación con los cuadros eléctricos con aislamiento de aire.

Sf6 Switchgear uses 10% of the space that Air Insulated Switchgear uses.

Esta característica aumenta sus áreas de aplicación.

· Distancia de fuga

Es una medida de la distancia más pequeña en la superficie del aislamiento entre dos materiales conductores.

Debido a la descarga eléctrica se produce corrosión alrededor de la superficie de esta región.

Por lo tanto, es importante mantener la distancia de fuga a través de un proceso llamado seguimiento.

Al comprobar el seguimiento, es necesario tener en cuenta el índice de seguimiento comparativo y el nivel de contaminación atmosférica.

· Mantenimiento

Sf6 Switchgear requires less maintenance, which helps in reducing the overall cost of the switchgear.

Esto se debe a que se producen menos fallos y a la naturaleza inerte del gas SF6.

Envíe su consulta hoy
Subir archivo
es_ESSpanish
Desplazarse hacia arriba